 *** Input Data *************


 *** N =  8 M =  2 UPPER =   T TOL = 0.1D-14


 *** Output Data ************


 *** Testing norm U*A0-A*U =0.152653D-14
 *** which should be of the order of the machine precision
 *** norm(A)
 *** Testing norm U*B0-B =0.387057D-15
 *** which should be of the order of the machine precision
 *** norm(B)
 *** Testing norm U*UP-I =0.117067D-14
 *** which should be of the order of the machine precision
1*** This first example is a well-conditioned one.
 *** The above norm tests should be close to the machine
 *** precision and A, B, U should be close to those obtained
 *** on any other machine.
1*** Second example : lower Hessenberg form


 *** Input Data *************


 *** N =  8 M =  3 UPPER =   F TOL = 0.1D-14


 *** Output Data ************


 *** Testing norm U*A0-A*U =0.175402D-14
 *** which should be of the order of the machine precision
 *** norm(A)
 *** Testing norm U*B0-B =0.341842D-15
 *** which should be of the order of the machine precision
 *** norm(B)
 *** Testing norm U*UP-I =0.110597D-14
 *** which should be of the order of the machine precision
1*** This second example is an ill-conditioned one.
 *** Therefore A, B and U can differ a lot from those obtained
 *** on another machine, but the above norm tests should yet
 *** be close to the machine precision (because of backward
 *** stability).