1


     START OF CERTIFICATION PROGRAM FOR THE DOUBLE PRECISION SPARSE BLAS
     -------------------------------------------------------------------

     NAME   OF OUTPUT UNIT              = res1                            
     NUMBER OF OUTPUT UNIT              =          6
     MAX. NO. OF PRINTED ERROR MESSAGES =        100
     THRESHOLD VALUE OF TEST RATIO      =        5.0

     NUMBER OF VALUES OF NZ        =         16

     VALUES OF NZ =    -1    0    1    2    5    9   31   32   33   63

     VALUES OF NZ =    64   65  127  128  129  257

     NUMBER OF VALUES OF A         =          3

     VALUES OF A =    0.0000D+00   1.0000D+00   7.0000D-01

     NUMBER OF VALUES OF C AND S   =          4

     VALUES OF C =    1.0000D+00   0.0000D+00  -6.0000D-01   8.0000D-01

     VALUES OF S =    0.0000D+00   1.0000D+00   8.0000D-01  -6.0000D-01

     DAXPYI PASSED ALL TESTS.

     DDOTI  PASSED ALL TESTS.

     DGTHR  PASSED ALL TESTS.

     DGTHRZ PASSED ALL TESTS.

     DROTI  PASSED ALL TESTS.

     DSCTR  PASSED ALL TESTS.

     DOUBLE PRECISION SPARSE BLAS HAVE PASSED ALL TESTS.